Air Atomizing Burners®

Specifications

 Burner Size & Type Equiv. Boiler Hp Oil GPH- 140,000 BTU/hr Oil GPH- 150,000 BTU/hr Gas CFH- 1000 BTU/hr Steam lbs./hr at 212'F Motor Gas Valve Size & Conn. Gas Press. at burner WC Inch Blower Motor Hp Air Comp. Motor Hp Oil Heater kw (144 only)
 60 PAE 60 18 16 2500 2080 2 5.5 1 1/2 1 1/2 1 X 5
 100 PAE 100 30 28 4200 3462 2 5.5 1 1/2 1 1/2 1 X 5
 150 PAE 150  45 42 6300 5193 3 5.5 3 1 1/2 1 X 5
 200 PAE 200 60 56 8400 6924 3 5 5 1 1/2 2 X 5
 250 PAE 250 75 70 10500 8655 3 6.5 7 1/2 1 1/2  2 X 5
 300 PAE 300 90 84 12600 10387 3 10 7 1/2 1 1/2 2 X 5
 200 AFA 200 60 56 8400 6924 3 5 3 1 1/2 2 X 5
 350 AFA 375 112 105 15700 12942 3 8.8 10 5 2 X 5
 400 AFA 400 120 112 16800 13849 3 9.8 15 5 2 X 5
 AE 500 500 150 139 20900 17500 3 8 20 3 3 X 5
 AE 600 600 180 167 25100 21000 3 12 30 5 3 X 5
 AE 700 700 210 195 29300 24000 3 18 30 5 3 X 5

These burners can burn gas & #2 oil (104), gas & #4 oil (114), and gas & #5, #6 oil (144).

The weight varies from 350 lbs to 3750 lbs.

Back ***** General ***** Guarantee ***** Home